Possible cause of electrical failure

Due to the gap or deviation during the electrical operation and maintenance electrical failure takes places and sometimes it becomes so fatal.
 a) Safety
1) Not using PPE
possible cause of electrical failure 
2) Poor lighting 
 3) In/exit path missing
 4) Using non-standard tools 
5) Not using LOTO
 6) Wrong tag marking 
7) In sufficient fire detector, fire extinguisher 8) Improper SOP for energization/de-energization 

  b) Monitoring issue 
 9) Irregularity in in taking reading 
 10) Relay failure
 11) Irregularity in PM
 12) Time coordination with up stream
 13) Setting coordination with up stream 
14) Numerous alarm 
15) Irregularity in in taking reading of UPS, Battery charger 
16) High temperature in VFD/UPS room 

  c) Marking on panel
17) Feeder cubical name 
 18) Rating 19) Fuse rating 
20) Cable size 
 21) Special marking 

  d) Functional 
22) non availability of emergency light for power restoration 
 23) Auto failure of bus coupler 
 24) Spare short fall 
 25) Non availability of testing equipment 
 26) ill weather 
27) poor maintenance

  e) Fire Hazard 
 28) flammable material in cable cellar 
 29) Non FLP equipment in battery room
 30) Improper spacing of fire extinguisher 
 31) Hydrocarbon ingress in substation 
 32) Failure of insulation

  f) Furious tripping 
 33) Wrong relay setting 
 34) Wrong operation 
 35) Wrong sequence of operation 
 36) Wrong control circuit 
 37) Breaker failure 
 38) Poor scheme 
 39) Poor design 

  g) Flashover 
 40) Failure of end termination 4
1) Lizard entry
 42) Unwanted light on at night 
 43) Aging of equipment 
 44) CT/PT failure 
 45) Water ingress in JB/DB 
 46) Rodent entry
 47) Moisture ingress
 48) Poor ventilation 
 49) Fire in capacitor of AC 

  h) Knowledge gap 
 50) Lack of training 
 51) Lack of knowledge 
 52) Improper monitoring

5 comments:

  1. Hey Nice Blog!!! Thank you for sharing information. Wonderful blog & good post. Its really helpful for me, waiting for a more new post. Keep Blogging!!!
    Energy Management System
    What is an Energy Management System


    ReplyDelete
  2. Are you looking for the best Commercial RO Plant Manufacturers in Delhi?
    There are numerous RO plant manufacturers available in Delhi that are providing high quality water treatment equipment.

    ReplyDelete
  3. Hey Nice Blog!!! Thank you for sharing information. Wonderful blog & good post. Its really helpful for me, waiting for a more new post. Keep Blogging!!!
    Importance of Harmonic Filtration for Steel Industry
    What is an Energy Management System

    ReplyDelete
  4. Electrical engineering is a worldwide subject, therefore you can easily relocate to any country and start a career there.You can also check out about Best College for Electrical Engineering in India here

    ReplyDelete
  5. 6 Gauge Terminal Lug are made from 99.9% pure annealed copper, providing a high degree of conductivity for maximum current flow. This particular variant is suitable for use with 6 Gauge Battery Cable & #10 (M5) Stud.

    ReplyDelete

SOP, Standard Operating Procedures

  1.1 .    Definition SOP is termed commonly as Standard Operating Procedures- SOP  Characteristics of SOP- 1)     Carry out the operati...