Relay no | Description |
2 | Time delay starting or closing |
3 | Checking/interlocking |
4 | Master contactor |
21 | Distance relay |
25 | Synchronizing relay |
27 | Under voltage relay |
30 | Enunciators relay |
32 | Directional power |
37 | Under current/ under power |
40 | Field failure |
46 | Phase balance current |
49 | Machine/transformer thermal |
50 | Instantaneous over current or rate of rise |
51 | AC time over current |
52 | AC circuit breaker |
52a | Circuit breaker auxiliary contact NO |
52b | Circuit breaker auxiliary contact NC |
55 | Power factor relay |
56 | Field application relay |
59 | Over voltage |
60 | Voltage or current balance |
64 | Earth fault |
67 | AC directional over current |
68 | Blocking relay |
74 | Alarm |
76 | DC over current |
78 | Phase angle measuring or out of step |
79 | AC re-closing |
81 | Frequency relay |
83 | Automatic selective control |
85 | Carrier or pilot wire receiver |
86 | Locking out or master trip |
87 | Differential protection |
94 | Anti pumping |
95 | Supervision |
96 | Bus differential |
63 | Buchholz relay |
49 | Transformer winding /oil temperature |
SHORT TAXT | |
CAG14 | High impedance differential relay with variable current setting |
CDAG | Over current relay with time delayed phase fault elements having any of the standard inverse characteristic plus an instantaneous earth fault element |
CDG11 | Inverse time over current relay with basic inverse time characteristic and a single contact on the disc |
CDV22 | Voltage controlled inverse time overcurrentrelay |
CTN | Negative phase sequence with inverse time characteristics for generator protection static |
CTS | Motor stalling relay |
DBAE4 | Rotor earth fault |
DTH | Static transformer percentage biased differential with harmonic restraint |
FMG11 | Over frequency relay |
FMG12 | Under frequency |
GTT | Over fluxing |
HORM4 | Tran slay plain feeder medium speed pilot wire |
TTT | Transformer oil/winding temp indicator with alarm and trip functions |
VAG11 | AC under voltage or over voltage with fixed setting |
VAG21 | AC under voltage or over voltage with fixed setting with drop off pick up ratio |
VAJH13 | Low burden high speed tripping relay with hand reset contact |
VAJ513 | Low burden high speed tripping relay with self reset contact |
VATX11 | High speed tripping relay with electrical or hand and electrical reset contact |
VAT | Independent (definite) time delay relay |
VAX12 | DC supply failure relay |
VAX21 | Trip circuit supervision relay when the circuit breaker is closed |
VAX31 | Trip circuit supervision relay when the circuit breaker is either open or closed. |
VDH12 | Inverse time natural displacement relay for use in distribution system |
VTT | Static definite time delay relay |
YEGF | Generator asynchronous running detection relay |
Wednesday, 18 April 2012
Relay numbering
Subscribe to:
Post Comments (Atom)
SOP for pest control or disinfestation in substation and switchgear rooms
1. OBJECTIVE a) To prevent the entry of lizards, rodents, and other pests inside electrical substations, MCC rooms, UPS rooms, battery rooms...

-
Winding and weight of induction and submersible motor – winding weight and motor weight Typical motor, 3 Ph, 40 H, 415v Sr. ...
-
TRANSFORMER 11/0.415 KV Sr TR KVA Un tanking Mass (core+ winding), KG Oil Mass, KG Total mas...
-
Busbar Bus bar A bus bar (also spelled busbar, buss bar or busbar), is a str...